Calibration of energy meter pdf

Energy meters that are installed within and according to the specifications of the installation document. Calibration this instrument has been calibrated to detect the total incident solar power of the sun. Testing and calibration of electricity meters in india. Based on energy meter measurements the customer gets a bill and has to pay for energy consumption. This together with a data collecting device dcd and a local computer forms a powerful system of metering and data logging. One convenient and simple way to interface the ade7754 to a display or energy register is to use a microcontroller mcu that reads on e of the active energy registers, e. In every residence, malls, industry, everywhere energy meters are used to measure the electrical energy consumed. Now calibration of energy meter means configuring your meter to rea. It is reliable and accurate hence it has demand in calibration testing laboratories, power energy meter manufacturers. Those consumers which consume large energy needs better technology to manage their energy consumption and need more data to improve their services. There are several other such laboratories under the control of government departments such as the.

Fast digital calibration procedure for stpm01 based energy meters introduction this document describes the fast digital calibration procedure enabled by stpm01 in solid state energy meters. Pdf the measurement of the electrical energy and its billing for tax purpose are of great relevance. The largest incident value of solar power is obtained when the end of the meter faces the sun directly. Portable energy meter calibrator available including three phase, single phase meter test equipment. Remote calibration system of a smart electrical energy meter.

Lowcost energy meter calibration method for measurement and verification. Using the 6100a electrical power standard to calibrate. Fast digital calibration procedure for stpm01 based energy. This display should show the amount of energy consumed in kwh k ilowatt hours. Note down the reading of two meters in a given period of time, say 2 minutes. The calibration system has the expanded uncertainty of 0. Highaccuracy laser pow er and energy meter cali bration servi ce david j. The meter demonstrates registration accuracy in accordance with the accuracy requirements of section 2. The electrode should never be rinsed in the same buffer beaker that will be used for calibration. Single phase power energy meter calibrator is used for calibration of energy meters, wattmeters, va meters, var meters, pf meters. But these are now being gradually replaced by electronic digital energy meters. The traditional calibration methods for analog energy meters are not applicable to digital energy meters. A calibration service for wattmeters and watthour meters author.

These standards support applications of lasers in manufacturing, electronics, medicine, communications, and the military, among other fields. After the final assembly phase, an energy meter requires a calibration procedure due to unknown sensitivities of its following blocks. Procedure for calibration and testing of singlephase energy meter. Customers need to know whether the powerlogic energy meter requires periodic calibration. Engineers working onsite test the accuracy of every energy meter and multifunction meters by using a standard reference meter of a better accuracy than meter being tested. When the end of the meter does not face the sun, the incident solar power is reduced by the cosine curve of the angle to the sun. Pdf lowcost energy meter calibration method for measurement.

There are three official calibration laboratories available worldwide for laser power meters and laser energy meters from genteceo. All multifunction meters are tested once in 3 years. Calibration and testing of singlephase energy meter. Give the connections as per the circuit diagram above.

Presented here is a simple energy meter using analog devices ade7757 chip for singlephase, 2wire phase and neutral systems used in households. Electromechanical energy meters have been the standard for metering the electricity since billing began. Each voltage phase is referred to the neutral and has 120 phase difference with the other phases see figure 2. Calibration led the focus kwh has an infrared light emitting diode led that emits energy pulses. The meter which is used for measuring the energy utilises by the electric load is known as the energy meter. Highaccuracy laser power and energy meter calibration service.

Digital energy meters are used in digital substations to measure electric energy, which receive iec 61850 digital input. Singlephase kwh meter calibrator accuracy calibration. Apr 23, 2017 to calibrate ac energy metet using reference energy meter in an easy way. It is used in domestic and industrial ac circuit for measuring the power consumption. The gf302d1 three phase portable energy meter test system consists of an integrated three phase current and voltage sourceup to 500v120a or 500v20a and builtin threephase electronic. Attached is a certificate of calibration for the powerlogic energy meter. A calibration service for wattmeters and watthour meters. Calibration method for digital energy meters in digital. Mar 28, 2017 induction type single phase energy meter.

In fact, it impacts directly on accuracy, cost, manufacturability and reliability of the meter. It describes the software used with the ade7754 evaluation board to perform the calibration. This type of metering and data logging gives a unique method for measurement of all. Electrical energy meters principles and applications. Utilities are one of the electrical departments, which install these instruments at every place like homes, industries, organizations, commercial buildings to charge for the electricity consumption by loads such as. Every meter which is being used to measure electrical energy for the first time is calibrated or is covered by a conformity evaluation in line with european mid m easuring i nstruments d irective guidelines. Cn106154207a electric energy meter error quick calibration.

Fast digital calibration procedure for stpm01 based energy meters. Energy meter or watthour meter is an electrical instrument that measures the amount of electrical energy used by the consumers. Energy meter circuit detailed project with source code. Calibration and testing of single phase energy meter. It is reliable and accurate hence it has demand in calibration. Energy meter testing, energy meter repairing, energy meter. If a meter is used in combination with a current transformer. During installation and commissioning, icd conducts complete calibration and testing of energy meters. Using the 6100a electrical power standard to calibrate energy. Energy meter testing, energy meter repairing, energy meter calibration, energy meter certification, energy meter servicing, mumbai, india. After turning on the meter, wait 3 to 5 seconds before use to allow builtup energy to discharge.

Power and energy calibrationkey test and measurement issues. Highaccuracy laser power and energy meter calibration. C to the pressure coil circuit by means of phase shifting transformer. Livigni national institute of standards and technology boulder, co 80303 this document describes the highac curacy laser power and energy meter calibration service provided by the national institute of. It is not possible for an individual unaffiliated with the utility company to calibrate the smart meter. This document discusses the interpretation and basis for stated measurement accuracy of ophir laser power energy meters. The energy is the total power consumed and utilised by the load at a particular interval of time. Nov 17, 2017 the gf302d1 three phase portable energy meter test system consists of an integrated three phase current and voltage sourceup to 500v120a or 500v20a and builtin threephase electronic. Detailed analysis of power and energy calibration errors. Pic18f87j72 singlephase energy meter calibration users guide. Calibration of ac energy meter using reference energy meter. Pic18f87j72 singlephase energy meter calibration users. Microchip energy meter software provides a detailed description of features of the calibration software tool, which is provided with the single.

The nist laser power and energy calibration project develops and maintains the u. Energy meter testing, energy meter repairing, energy meter calibration, energy meter certification, energy meter servicing, mumbai, india wowslideshow by v8. The user can set voltage, current, frequency, power factor etc. This application note describes how to calibrate the ade71xx.

This application note describes the different steps to calibrate a 3phase 4wire, 3element energy meter based on the ade7754. Today there is a better way to run this cali bration. Calibration is a process of elimination of errors by configuring an instrument to provide a result within an acceptable range. The electronic energy meter is also better protected against tampering than its mechanical predecessor, and units for prepaid operation e. The ade7754 is comprised of six adcs, a reference circuit, and all the signal processing necessary for the calculation of active energy, apparent energy, and rms. For the low electric energy meter of required precision, generally use calibration of power mode, i. The first section details the calibration procedure, providing equations and examples of. Calibration of single phase energy meter using phantom loading method with rss meter as standard.

Measurement of 3 phase power with single watt meter and 2 nos of c. Pdf on the remote calibration of electrical energy meters. This allows the user to run the meter for a userdefinable period of time, so that the energy meter can reach a suitable operating temperature, prior to testing. Remote calibration system of a smart electrical energy meter article pdf available in journal of electrical systems 4. Pdf remote calibration system of a smart electrical energy. Induction type energy meter used invariably to measure the energy consumed in any a. This calibration steps exist electric energy meter power jump difference cause calibration after the big. Understandingiso17025forlaserpowerandenergymeasurement formfirst. Smart meters differ from regular home energy monitors in that they can send data to the energy company while regular energy meters cannot.

In this report, we describe the calibration methods, systems, and uncertainties in the frequency range 100 khz to 110 ghz. Technical note ph calibration procedure for optimal. The calibration screw is located on the top of the meter under the probe receptacle. Pic18f87j72 singlephase energy meter calibration users guide 2011 microchip technology inc.

419 393 459 1162 1101 880 468 1373 726 1432 582 1448 123 948 905 1553 618 553 97 1345 144 812 1446 434 16 655 1475 1028 1131